Ecoflam Hot Water Burner
25000 INR/Unit
Product Details:
- Color Red and Black
- Condition New
- Type Once Through
- Usage Industrial
- Structure Water Tube
- Pressure High Pressure
- Material Metal
- Click to View more
X
Ecoflam Hot Water Burner Price And Quantity
- 25000 INR/Unit
- 1 Unit
Ecoflam Hot Water Burner Product Specifications
- Industrial
- High Pressure
- Water Tube
- Red and Black
- Metal
- Once Through
- New
Ecoflam Hot Water Burner Trade Information
- Cash on Delivery (COD) Cash Advance (CA) Telegraphic Transfer (T/T) Cash in Advance (CID) Cheque
- 1000 Unit Per Week
- 1 Days
- Yes
- Sample costs shipping and taxes has to be paid by the buyer
- Western Europe Australia Middle East Eastern Europe South America Asia Central America North America Africa
- All India
Product Description
Ecoflam Hot Water Burner
Ecomax Hot water Boiler installed in multi storey hotels. For hot water.
MAIN FEATURES:
- Completely sealed aluminum casing with a new modern design cover.
- New high efficiency fan ventilation system (HPV) allowing easy matching with boilers having high combustion chamber back pressure.
- Compact burner dimension with low noise levels.
- New air damper with progressive micrometric air regulation adjustable in 3 positions.
- Air damper with 60 or 80 mm snorkel adaptor (optional).
- New electrical wiring simple to disassemble for easy maintenance.
- Combustion head easy to assemble and adjust for fine set up.
- Single bolt burner fixing and the possibility to firmly secure it to the flange in three different positions for easier maintenance.
- Ease of installation with adjustable flange (optional only for TL from Max 1 to Max 12).
- Monoblock electrodes for easy and steady installation into the nozzle even after maintenance.
- Hi - Low version available with compact hydraulic system (Max AB HS).
- Low NOx version with yellow flame developed by Ecoflam.
- Max range available with "D" pump for light oil with viscosity up to 200 cTs.
- Kit for biodiesel on request.
- Continuous ventilation on request.
TECHNICAL DATA:
MODELS | Output | Output | ||
| kW | kcal/hx1000 | kW | kcal/hx1000 |
MAX 1 | 41.4 | 35.7 | 17,6 | 15,3 |
MAX 1 Low NOx | 35.5 | 30.6 | 17,6 | 15,3 |
MAX 4 | 59 | 51 | 20 | 17,34 |
MAX 4 Low NOx | 47.4 | 40.8 | 22,5 | 19,35 |
MAX 8 | 105 | 90.78 | 47 | 40,8 |
MAX 12 | 130 | 112.2 | 60 | 52 |
MAX 15 | 190 | 163.8 | 73.4 | 63.24 |
MAX 20 | 237 | 204 | 86.4 | 74.460 |
MAX 30 | 319 | 275.4 | 110 | 94.860 |
MAX P15 / P15AB HS | 190 | 163.8 | 77 | 66.3 |
MAX P25 / P25AB HS | 300 | 259.08 | 102 | 87.72 |
Fuel : Light oil (L.C.V. 10.200 kcal/kg max. visc 1,5°E at 20°C) | ||||
Combustible : Fioul domestique (L.C.V. 10.200 kcal/kg max. visc 1,5°E at 20°C) |
Get in touch with us